FGCD Series Lithium Battery Discharge-Charge Unit
Hotline:86-591-83305821
E-mail:global@fuguang.com

Overview

FGCD series adopts advanced charging and discharging technology with a variety of built-in test and maintenance modes. It is suitable for discharge, charge and cycle charge and discharge tests of various types of lithium battery packs.

When the EVs cannot be fully charged or the voltage is insufficient, the FGCD Battery Discharge-Charge Unit can detect the actual capacity of the module through the discharge mode before the maintenance, and perform supplementary electricity and capacity calibration after the maintenance to verify that the cruising range of the capacity has reached the expectation. FGCD integrates charge and discharge and cell monitoring functions into one unit, communicates with the BMS of the battery pack, and can quickly and intuitively read cell info and screen out lagging cells, greatly reducing the maintenance workload. At the same time, using the FGCD can greatly reduce the cost of battery replacement, increase the battery utilization rate, and reduce maintenance and use costs.


Application
Battery Manufacturers: after-sales, warehousing, TVC testing, QA and other battery testing
EV OEMs: battery maintenance
Service Providers: aftermarket maintenance in module charging, discharging and quick matching


Functional Characteristics


One Machine with Multi-function: wide range design is suitable for discharge, charge and activation tests of battery packs in various voltage levels.

Multi-Discharge Modes: adopt efficient aerospace load materials and advanced control technology to ensure discharge accuracy.
High-Efficiency Charging Mode: ensure that the battery pack is fully charged to greatly improve the charging efficiency.
Battery Pack Activation: freely set charge and discharge rules and activation times to effectively improve the battery capacity.

Communication Method: CAN, RS485.

Data Acquisition: it can collect the max and min voltage, temperature, and other data during the test. The operating interface will show the data in various ways like bar chart, form, and curve.

Protection: the tester will prompt alarms and beep in various situations, such as reversed polarity connection, over-temperature, short-circuit overcurrent, fan fault, over-voltage, overcurrent, etc.

Operating Display


1686884999589468.png 1686884999159591.png

1686885000178305.png 1686885000897970.png

1686885000151953.png 1686885001110941.png


Technical Parameter


Model

FGCD-A200CT

FGCD-A300CT

FGCD-10030NT

FGCD-60030NT

Group Voltage Range

DC 2-285V

DC 2-285V

DC 2-100V

DC 200-600V

Accuracy & Resolution

±0.5%FS

±0.5%FS

±0.5%FS

±0.5%FS

Cell Voltage Range

0-5V

0-5V

0-5V

0-5V

Accuracy & Resolution

0.001V

0.001V

0.001V

0.001V

Discharge Current Range

0-100A/7.2KW

0-100A/7.2KW

0-30A/2KW

0-30A/18KW

Accuracy & Resolution

±1%FS

±1%FS

±1%FS

±1%FS

Charge Current Range

0-80A/4.4KW

0-80A/6.6KW

0-30A/2KW

0-20A/12KW

Accuracy & Resolution

±1%FS

±1%FS

±1%FS

±1%FS

Power Supply

AC220V

AC220V

AC220V

AC380V

Working Mode

discharge, charge, activation

Communication (PC)

RS485, CAN

Protection

DC input over voltage, polarity reversal, discharge over current, over temperature

Dimension (mm)

512*295*339

512*295*339

452*234*286

680*554*334

Weight (kg)

25

28

18

40


Contact

WhatsApp

Alibaba

Tik Tok

TOP