ABE-2612CT Intelligent Battery Activator & Discharger
  • Description
  • Specification
  • Download


n   Discharger & Charger for 1.2V/2V/6V/12V single battery

5.7 inch LCD touch screen for easy operation and showing various parameters real time

Support up to 9 cycles discharge/charge autorun

Adjustable stop points and multiple alarm designs to control the test process intelligently

Support RS232 real time monitoring by PC or USB download data after discharge

PC software for capacity evaluation and report generation



1.2V/2V/6V/12V discharger & Charger

ABE-2612CT can support 1.2V/2V/6V/12V battery discharge & charge

Multiple Adjustable Stop Points

ABE-2612CT offers multiple adjustable points fortest stop points to avoid excessive discharge & charge.


Multiple Protections & Alarms

ABE-2612CT provides ample protective measures for various abnormal situations during testing. Automatic termination, LCD prompt and beep warning would assist users to make proper treatments.

5.7 inch Touch LCD Display

Super big size touch LCD can display all realtime data and graphs and support the click operations directly, humanized input method and menu designs simplified operating process.



PC Analysis Software

Support data downloading and analyzing through real time communication or USB memory devices.

The software interface includes: battery voltages curve, current curve, capacities histogram, data form and so on.

The software shows the data by various ways like bar charts, curve, and form. And users can magnify or minify any windows to read more details.

Automatically create EXCEL data report, it’s so convenient to send or download the data.

Internal Memory

ABE-2612CT can save several independent discharge & charge records automatically without Laptop monitoring, non-volatileinternal memory guarantees the data security even in unexpected shutdown.

The menu interface provides some management operations like reviewing, deleting, downloading to PC by USB disk or RS232




Discharge & Charge Ranges

CE Certificate

Voltage rangecurrent range
LVD standards2006/95/EC: EN 61010-1:200
0.9 – 1.8V0-60 A
EMC standards2004/108/EC Annex II:
1.7 - 2.4V0-100 A

EN 61000-6-1:2007
5.1 - 15V0-30 A

EN 61000-6-3:2007

Current measurement



EN 61000-3-2:2006+A2:2009
current range0-100 A

EN 61000-3-3:2008
Accuracy & resolution≤±0.5%, 0.1 A

Environment

Voltage measurement


Operation temperature-5 to 50o C
Voltage range 11.7- 2.4V
Storage temperature-40 to 70o C
Accuracy & resolution≤±1%, 0.01 V
Humidity5% - 95% RH
Voltage range 25.1 - 15V
Altitudebelow 4000 m
Accuracy & resolution≤±0.25%, 0.1 V
Working noise<60 dB

Power Supply


Dimensions & Weight

Power supply voltage220 V AC (-20% to +30%)
Main tester348 x 222 x 256 mm
Frequency50/60 Hz
Carrying case460 x 300 x 500 mm
Power consumption350W(max)
Weight10 kg (main tester only)

Communication & Storage



19 kg (included all accessories and carryingcase)
Communicate portUSB/RS232


Internal memory8Mbit Flash



Previous:FBC-200CT Battery Discharge Cycler